微型保偏光纤器件 weixingbaopianguangxianqijian
https://wisefox2018.oss-accelerate.aliyuncs.com/www.csrayzer.com/uploadfiles/image/20190620/20190620115638330.jpg
保偏光纤密集波分复用器 Polarization Maintaining Dense Wavelength Division Multiplexer

保偏光纤密集波分复用技术,也就是人们常说的DWDM,指的是一种光纤数据传输技术,这一技术利用激光的波长按照比特位并行传输或者字符串行传输方式在光纤内传送数据。DWDM是光纤网络的重要组成部分,它可以让IP协议、...

产品详情资料下载

保偏光纤密集波分复用技术,也就是人们常说的DWDM,指的是一种光纤数据传输技术,这一技术利用激光的波长按照比特位并行传输或者字符串行传输方式在光纤内传送数据。 DWDM是光纤网络的重要组成部分,它可以让IP协议、ATM和同步光纤网络/同步数字序列(SONET/SDH)协议下承载的电子邮件、视频、多媒体、数据和语音等数据都通过统一的光纤层传输。

Polarization-maintaining fiber Dense Wavelength Division Multiplexing (DWDM) is a kind of optical fiber data transmission technology, which uses the wavelength of laser to transmit data in the optical fiber in parallel or in serial mode. DWDM is an important component of optical fiber network. It enables data such as e-mail, video, multimedia, data and voice carried by IP protocol, ATM and synchronous optical fiber network/synchronous digital sequence (SONET/SDH) protocol to be transmitted through a unified optical fiber layer.

应用领域  Application area  

·测试设备 Testing Equipment      

·光纤通信Fiber Communication

·光纤传感 Fiber Sensor


技术指标


参数(Parameters)

单位(Unit)

指标(Values)

膜片类型


200Ghz

100Ghz

Pass Band

波长范围( Wavelength Range)

nm

ITU Grid

典型带宽@0.5dB(Typ. Bandwidth)

dB

0.7

0.4

最小带宽@0.5dB(Min. Bandwidth)

dB

0.5

0.2

典型通道隔离度(Typ.Channel Isolation @C→P )

dB

30

30

最小通道隔离度(Min.Channel Isolation @C→P)

dB

25

25

典型插损(Typ. Insertion Loss@ C→P)

dB

0.6

0.8

最大插损(Max. Insertion Loss@ C→P)

dB

1.0

1.2

Reflection Band

典型通道隔离度(Typ.Channel Isolation @C→R )

dB

15

15

最小通道隔离度(Min.Channel Isolation @C→R)

dB

13

13

典型插损(Typ. Insertion Loss@ C→R)

dB

0.3

0.3

最大插损(Max. Insertion Loss@ C→R)

dB

0.5

0.5

最小回波损耗(Min. Return Loss)

dB

50

典型消光比(Typ. Extinction Ratio )

dB

23

最小消光比 (Min. Extinction Ratio)

dB

20

最小方向性(Min. Directivity)

dB

45

波长温度漂移(Center Wavelength Stability)

nm/℃

≤0.002

温度稳定性(Thermal Stability)

dB/℃

≤0.005

最大承载功率(Max. Handing Power)

mW

500

光纤类型(Fiber Type)

--

PM Panda Fiber

承载拉力(Max. Tensile Load)

N

5

工作温度(Operating Temperature)

-45 to +70

存储温度(Storage Temperature)

-55 to +85

备注:

*以上指标是不加连接头的参数.(Above specification are for component without connector)

*对于增加连接头的器件,,回损将会降低5dB,消光比也会降低2dB左右.( RL will be 5dB lower and ER will be 2dB lower for component with connector)

*保偏光纤和连接器是慢轴对准。(The PM fiber and connector key are aligned to the slow axis)



订货信息

PMDWDM-①-②-③-④-⑤-⑥-⑦

①通道间隔
Channel Spacing
②中心波长
Center Wavelength
③封装尺寸
Package Dimension
④光纤类型
Fiber Type
⑤光纤长度
Fiber Length
⑥套管
Fiber Jacket
⑦连接器
Connector
1-100GhzCHxx-ITU Grid5.5×35-5×35mmPM1550—PM1550 Panda Fiber1-1M0-Bare FiberN-None
2-200Ghz
3.2×30-3.2×30mmSpecify-客户指定1.5-1.5M1-900um Loose TubeFU-FC/UPC




Specify-客户指定2-2mm CableFA-FC/APC





3-3mm Cable